Desertcart purchases this item on your behalf and handles shipping, customs, and support to Spain.
โก Upgrade your oil burner game with smart, sleek control!
The Honeywell R7284U-1004 is a universal electronic oil primary controller featuring a 16-character two-line tri-lingual LCD display for easy programming and diagnostics. It offers fully programmable parameters, LED and display fault alerts, and requires no additional tools to access all features. Designed for compatibility with a broad range of oil burners, it enhances burner efficiency, reliability, and maintenance easeโperfect for professionals upgrading legacy systems or optimizing current setups.
| ASIN | B0058UHG5Y |
| Best Sellers Rank | #260,424 in Tools & Home Improvement ( See Top 100 in Tools & Home Improvement ) #105 in HVAC Controls |
| Brand | Honeywell |
| Brand Name | Honeywell |
| Color | Color |
| Customer Reviews | 4.6 out of 5 stars 444 Reviews |
| Display Type | LCD |
| Global Trade Identification Number | 00085267344708 |
| Included Components | Honeywell R7284U-1004 Universal Electronic Oil Primary with Programmable Parameters and LCD Display |
| Item Type Name | Electronic Oil Primary |
| Item Weight | 1.5 Pounds |
| Manufacturer | Honeywell |
| Model | R7284U-1004 |
| Part Number | R7284U1004 |
| Smart Home Compatibility | Not Smart Home Compatible |
| UPC | 085267344708 094714274482 |
| Unit Count | 1.0 Count |
| Warranty Description | No Warranty |
C**R
4+ years and works great so far
I bought this to replace the original old school controller in my 90s Intertherm oil furnace. I also bought an electronic ignition coil and an oil cutoff valve and a new electrode set and filter to go with it. I really like it having the ability to run the Beckett burner motor before turning on the oil and then turning off the oil before shutting the motor off because of the much cleaner start and stop as far as the nozzle is concerned. Also I use the interrupted spark mode which is so much easier on the electrodes. The ability to read the ignition time history and the CAD cell resistance real time helped my find a problem with my nozzle holder as well. I am relying on the latter two readings to tell me when to change the nozzle and electrodes now after removing it after the first winter and seeing how clean they were.
R**R
GREAT CONTROLLER, GREAT VALUE FOR THE COST!
I have a 140MBTU Burnham Boiler that the failed during a snow storm of course. No parts where available, so I ordered from Amazon. The parts arrived within 5 days due to weather. I have a Honeywell 3 wire primary oil burner controller, and found the directions quite lacking having installed many oil burners throughout my years as a general contractor. I read the reviews, and I appreciated some of the very detailed comments, which did shed light on the installation instructions (or lack thereof). I have included some diagrams and photos of my boiler to assist those of you who may not understand what others have described, as this really is not that difficult to do. I have also listed some other things to consider while you are reading this getting ready to order. You should have a 3/8 combination wrench (Oil bleeder). 7/16 combo wrench (Oil pump supply tube), 5/8" combo wrench (Nozzle & Oil Filter Housing), Pliers (Slip joint or waterpump), Needle Nose to pull wires, A flat heat and Philips screwdriver, A small cleaning brush, wire strippers, crimpers, electrical tape, AC Volt Meter or DMM, some foil pans & rags, cleaner degreaser, a flashlight, and a few braincells that still function would be helpful. Along with the tools, there are parts you really should consider. Doing a full servicing while you are down, if you haven't already is not only smart, it's a lot easier since you are taking the motor apart already. 1 Order a new igniter, as this will only help if you are already having issues, its 2 wires and 4 screws, that's it, the Beckett unit was $59 on Amazon with 3 day delivery and it included a CAD cell complete with the gaskets 2 Make sure you replace the COMPLETE cad cell and wiring harness, as it is cheap insurance if your not planning on doing the igniter, or if it is new. Make sure you clean the igniter springs thoroughly 3 Replace your oil nozzle, the Delvans have it stamped right on the nozzle (80A 1.25) etc, or look on the boiler 4 Replace your oil filter, the gaskets on it, and clean or replace the oil pump screen & gasket 5 Order 25 pack of Blue T&B butt connectors to use the factory supplied color coded jumpers with insulated connectors already on them supplied with the new controller 6 Order 25' of 14ga Stranded Red and Black primary wire, you will use this for the installation 7 Pick up some degreaser/ cleaner, a small brush to clean with, and some Odor control spray for the fuel oil 8 Pick up some small foil pans at the grocery store to catch oil under the parts you are servicing. 9 WHILE YOUR AT IT, BUY A BOTTLE OF ALCHOHOL, IT ALWAYS HELPS. 10 Read the programming notes on the diagram, these are for a Boiler, not a furnace, if you have a furnace set the Type: FURN, and you can change the Ignition time to up to 45 seconds. A BOILER SHOULD BE MAX 15 LAST BUT NOT LEAST: MAKE SURE YOU TURN OFF THE ELECTRIC AT THE PANEL! Turn the thermostat to "Off". When you do the initial power up, you can go into programming without the thermostat calling for heat. turn off the service switch at the boiler for safety, then shut off the oil line at the tank to prevent leaks while servicing.
W**Z
Better thanBetter than snow.
Seems to be working, okay.
R**Y
Great item
Works as it should great item
J**E
Replaced R8184G 4009 Perfectly! (after a little trial and error)
I replaced a failed R8184G 4009 with this unit, and this works perfectly. I replaced the R8184G on my Beckett oil furnace with this for several reasons: 1. R8184G failed. 2. R8184G wasn't available locally within 3 days in the dead of winter. Even my local heater technician didn't have one on hand. If he *WOULD HAVE* had it, he would have charged me over $500 to install this unit!! (It took about 10 minutes to install and 30 minutes of trial and error to get the menu settings correctly configured) 3. This was actually CHEAPER! 4. I could get this delivered in about 14 hours, ordering it at 6:30PM on Monday night. It arrived by 8AM the next morning. With free Prime shipping. Since the R8184G is a 3-wire unit, this took a little figuring out to hook it up correctly, then some more figuring to set the menu up correctly. Wiring: Black AND red wire on R7284 connected to where the black wire used to go on my R8184. White wire on R7284 went where white wire used to go on R8184. Orange wire on R7284 went where red wire used to go on R8184. Yellow CAD wires on R7284 went to same yellow wires that were connected to the front of the R8184. My thermostat wires from the front of the R8184 went to the front TT terminals on the R7284. Menu settings: I originally tried to use some of the new fancy settings on the R7284. If upgrading from the R8184, don't try to use those settings. You would have to change the wiring for it to work. It caused me several hard lockouts to learn this lesson. Final working menu settings: Valve On Delay: 0 seconds Ignition time: 45 seconds matches the R8184G. THIS one you can change if you prefer. Burner Off Delay: 0 seconds TT Configured: No Spark In On Dly: No Spark During Run: No Allowed Resets: Your choice Appliance Type: FURN (for my oil furnace) Show Diagnostics: Your choice Installer Setup: Quit Re-Baseline: Yes It's working perfectly for me and I have blessed heat again. The replacement was very easy once I figured all the connections and settings out.
D**T
Perfect replacement and adjustable.
Word perfectly and love the ability to change the parameters on the front panel. I did have to run a constant hot wire for my burner, but is a direct replacement.
G**G
Huge upgrade over older Protectorelay
Bought to replace an old, failed R8184G. So far, seems like a huge upgrade. Instructions weren't the best, they seem to be targeted at someone with a significant amount of HVAC experience. Make sure to verify whether you have intermittent ignition and to wire properly based on the diagrams -- it's not 100% clear. The status display was amazingly helpful in troubleshooting a thermostat issue. All in all, cheaper and superior option to the older model ignitions. Pros: * Wiring now uses quick connect spade terminals. Wires are included for every terminal * Truly universal ignition -- can configure it for any number of options to replace nearly any older ignition model * Display provides a ton of help troubleshooting thermostat problems * Shows resistance output from safety sensor cell to help in troubleshooting ignition issues related to the photosensor Cons: * Manual isn't as complete as it could be -- if you're familiar with HVAC and wiring, you'll be fine, but it leaves something to be desired * Unit is much wider and taller than older Protecotrelay ignitions -- clearance could be an issue depending on your furnace layout. Make sure to measure before purchase to make sure it won't be an issue. I needed to move my fan power supply to make enough clearance room If you need to replace an older ignition, don't buy the older ignition. Buy this. It's an upgrade in every way.
D**D
Thank you, Joe! I also replaced a failing R8184G 4009 with this unit
Relays started sticking on my 38+ year old R8184G 4009 on a Carlin 100 CRD. Cleaned once but faulted again after 3 days, cleaned again and needed a reliable fix. I have Franken Controls based on a 70 yr old install of a Burnam Coal/ Oil, Steam or HW boiler with 2 added zones w/ a Taco 503 in 2000. Had a problem 2 yrs ago and 2 boiler techs were stumped. Fortunately fixed w/ a $25 transformer patched in but I had to figure it out. So, I was worried that I would have to get a direct replacement of the R8184G 4009 for $70 more than this R7284 unit and 2 weeks from Amazon. This unit wasnโt supposed to arrive until next week. Just in case, I did find a R8184G 4009 at the โBig Orangeโ but it was $180 so was hoping this would come in time for the weekend and work out. It came in 2 days! I read Joeโs instructions and mostly followed them. I was nervous about tying both the red and black terminals to the 120 hot so first tried it w/o the red connected. No-Go. Connected the red and all was well. I did connect the igniter (blue) and Motor (orange) separately vs ganged together as my R8184G 4009 had done. Also ran separate neutrals vs ganging them all w/ a wire nut as was done on mine before. Setup was easy thanks to Joe and having the CAD cell display and diagnostics makes it look like itโs at least from the late 20th century vs. beginning of it. It was also an inexpensive fix at the end, the R8184G 4009 can go back to HD. I did have constant 120V to the jct box so did not have to run a line as others have. Thank you Joe and others for the great info. Now I can travel this weekend in peace not worrying about a cold house.
R**E
Once hooked up, works great
Thank you to Rey for the directions on how to wire this up. Without that direction I would have been lost. Follow what is written and it will work perfectly. I errored in my first hook up and kept getting a "HARD LOCKOUT". Turns out I put 4 wires together, when it should have been blue to blue. Once separated, it ran perfectly. Took me longer than 20 minutes, but if I had not combined those four wires, it would have easily been done in 20 minutes. Thank you again Rey! Great directions, sure better than the booklet with the unit. :-)
R**H
Wiring
The directions were not clear on how to wire the controller. They do not say that when wiring the controller the limit and the hot line needs to be energized in order for it to work.
G**.
Works great but Honeywell's installation instructions are a little vague.
This controller works as expected and its nice to have the readout for diagnosis but I think Honeywell fell short with their installation instructions. I'm not a dummy when it comes to installing things like this yet I was scratching my head with this one. Finally figured it out after a call to my dad (retired plumbing and heating contractor) for some advice.
D**N
Great product
Works awesome, easy to install, thanks.
D**R
service
good product and dilivery
Trustpilot
3 weeks ago
1 week ago